Reinforcing bars
Corrosion-resistant fiberglass reinforcing bars for maintenance-free reinforcement with a long service life.
Get a free quote
Fill in the form below and we will contact you.
Corrosion-resistant fiberglass reinforcing bars for maintenance-free reinforcement with a long service life. Our corrosion-resistant fiberglass reinforcing bars have a very long functional lifespan, making them a cost-effective alternative to wood, concrete, and steel. They require minimal maintenance, even in corrosive and aggressive environments.
Fiberglass reinforcing bars (GRP) are a corrosion-free alternative to traditional steel reinforcement and are particularly well suited for constructions in aggressive environments, such as exposure to salt, moisture, or chemicals.Unlike steel, GRP does not deteriorate from corrosion, which extends the lifespan of building components and minimizes the need for repairs. The material is also lightweight, easy to work with without special tools, and requires virtually no maintenance.Common applications for GRP reinforcing bars include coastal constructions, bridges, wastewater facilities, and various industrial environments.
Steel vs GRP – a comparison table
| Characteristics | Steel Reinforcement | GRP Reinforcement |
|---|---|---|
| Material of construction | Steel reinforcement | GRP |
| Tensile strenght, Mpa | 360-390 | 1200-1300 |
| E-modulus, Mpa | 200000 | 60000 |
| Elongation at fracture, % | 25 | 2,2 |
| Lin. expansion- coefficient, 10-6/K |
13-15 | 9-12 |
| Density, kg/dm³ | 7 | 1,9 |
| Length | 6-12 m | 6 m or at request |
| Corrosion- and chemical resistance |
no | yes |
| Thermal conductivity | yes | no |
| Dielectric | no | yes |
| Radiotranslucent | no | yes |
| Insensitive to electromagnetic fields |
no | yes |
| life expectancy | 30 years | 100 years |
Tolerances
| Property | Dimension / condition | Tolerance |
|---|---|---|
| Height and width | All dimensions | ±0.5%, at least ±0.20 mm and at most ±0.75 mm |
| Diameter, tubes and rods | 0–10 mm | ±0.20 mm |
| Over 10–20 mm | ±0.30 mm | |
| Over 20–50 mm | ±0.35 mm | |
| Over 50–100 mm | ±0.40 mm | |
| Over 100 mm | ±0.45 mm | |
| Wall thickness T1 / T2 | 0–2 mm | ±0.15 / ±0.30 mm |
| Over 2–5 mm | ±0.20 / ±0.35 mm | |
| Over 5–10 mm | ±0.35 / ±0.45 mm | |
| Over 10 mm | ±0.45 / ±0.50 mm | |
| Transverse flatness | B = profile width | F < 0.008 × B |
| Angular deviation | Profile corner angle | ±1.5° |
| Straightness | Width or height under 50 mm | D < 0.002 × L² |
| Width or height 50–100 mm | D < 0.001 × L² | |
| Width or height 100 mm or more | D < 0.0005 × L² | |
| Twist | Material thickness under 5 mm | Max 1.5° per metre |
| Material thickness 5 mm or more | Max 1.0° per metre | |
| Cut length | All lengths | +20 / −0 mm |
| Angle of cut | All dimensions | ±1.5° |
| The stated tolerances are general guideline values. Where dimensional accuracy is critical, we recommend checking the tolerances for the specific profile and dimension. | ||